Combining Lumipulse pTau217 and Aβ42 as confirmatory tests for Aβ pathology prior to DMT
Abstract   Open access   Peer reviewed

Combining Lumipulse pTau217 and Aβ42 as confirmatory tests for Aβ pathology prior to DMT

James D Doecke, Ahmed Chenna, Mintzu Lo, Youssouf Badal, Brandon Yee, Robert L Martone, Christos Petropoulos, Christopher J Fowler, Simon M Laws, Stephanie R Rainey-Smith, …
Alzheimer's & dementia, Vol.21(Supp 2), e104702
2025
pdf
Published493.49 kBDownloadView
Published (Version of Record)CC BY V4.0 Open Access

Abstract

Background With the increasing number of countries approving disease-modifying therapies (DMTs) for patients with either Mild Cognitive Impairment (MCI) or mild Alzheimer's disease (AD), it is vitally important to streamline treatment assessment processes. Blood-based biomarkers (BBMs) have been suggested as rivals to cerebrospinal fluid (CSF) biomarkers in their accuracy to detect neocortical Amyloid-Beta (Aβ). However, there is little consensus on potential thresholds and resulting confirmatory test performance for international use in target populations. Method Two separate sub-cohorts—the AD continuum cohort (ADCC) [cognitively impaired + unimpaired; N = 197] and the intention to treat cohort (ITTC) [cognitively impaired; N = 200]—from the Australian Imaging Biomarkers and Lifestyle (AIBL) study of aging, were designed to test the accuracy and potential cut-offs of leading BBM Lumipulse assays from Fujirebio (pTau217 and Aβ42/40) to detect PET-Aβ (centiloid ≥25; amyloid prevalence ∼63%). Result Using the pTau217/Aβ42 ratio significantly improved the area under the curve (AUC) over pTau217 alone to detect PET-Aβ positivity in both the ADCC and ITTC (Figure 1A, ADCC p = 0.01; Figure 1B: ITTC p = 0.009). The Youden's Index cut-off for pTau217 was higher in the ITTC compared to the ADCC (0.25 pg/mL vs. 0.179 pg/mL). The highest accuracy observed for either single BBMs, the ratio of BBMs, or the linear combination of BBMs that included age, gender, and APOE ε4 was 93-95% in the ADCC (linear combination of pTau217, Aβ42/40, age, gender, and APOE ε4; pTau217/Aβ42 ratio) and 95-97% in the ITTC ( linear combination; pTau217/Aβ42 ratio). The lowest number of participants in the intermediate zone using dual cut-offs at 95% sensitivity and specificity was 9% and 14% for the pTau217/Aβ42 ratio in the ADCC and ITTC (92-93% accuracy), and 0% for the linear combination (pTau217, Aβ42/40, age, gender, and APOE ε4) in the ITTC (95% accuracy). Conclusion The general performance of the Lumipulse assays was similar across both the ADCC and ITTC, indicating strong repeatability independent of clinical stage. Focusing on only participants eligible for DMTs increased sensitivity and improved accuracy for the Aβ-containing pTau217/Aβ42 ratio and linear combination of markers, and resulted in small numbers of unclassified participants by the test.

Details

UN Sustainable Development Goals (SDGs)

This output has contributed to the advancement of the following goals:

#3 Good Health and Well-Being

Metrics

3 Record Views
Logo image