Logo image
A GR/Impedance probe proves unsuitable for measuring GR depth in Australian lamb carcases
Journal article   Open access   Peer reviewed

A GR/Impedance probe proves unsuitable for measuring GR depth in Australian lamb carcases

S.M. Fowler, J.M. Hoban, R. van de Ven, M. Boyce, A. Williams, D.W. Pethick and D.L. Hopkins
Meat Science, Vol.129, pp.71-73
2017
pdf
GR-Impedance-probe.pdfDownloadView
Author’s VersionCC BY-NC-ND V4.0 Open Access
url
Link to Published Version *Subscription may be requiredView

Abstract

Multiple studies were conducted at 3 abattoirs to determine the potential of a dual function GR/Impedance probe to measure GR soft- tissue depth (depth at the 12th rib, 110 mm from the mid line of the carcase) of typical lamb carcases processed in Australia. Lamb carcases (1016) were measured approximately 25 min post slaughter with the probe and a GR knife as the most commonly used measurement. Modelling indicated that variation in the measurement using the probe compared to the measurement using the knife occurred with increasing carcase weight and fatness as well as between different abattoirs. Consequently, the probe in its current design cannot provide the repeatable measurement required by industry