Logo image
Assessment of the plethysmographic variability index as a predictor of fluid responsiveness in critically ill patients: a pilot study
Journal article   Peer reviewed

Assessment of the plethysmographic variability index as a predictor of fluid responsiveness in critically ill patients: a pilot study

A.K. Baker, R.J.O. Partridge, E. Litton and K.M. Ho
Anaesthesia and Intensive Care, Vol.41(6), pp.736-741
11/2013

Abstract

fluid therapy haemodynamic monitoring preload pulse variations
Optimising intravascular volume in patients with hypotension requiring vasopressor support is a key challenge of critical care medicine. The optimal haemodynamic parameter to assess fluid responsiveness in critically ill patients, particularly those requiring a noradrenaline infusion and mechanical ventilation, remains uncertain. This pilot study assessed the accuracy of the plethysmographic variability index (PVI), (Radical-7 pulse co-oximeter, Masimo®, Irvine, CA, USA) in predicting fluid responsiveness in 25 patients who required noradrenaline infusion to maintain mean arterial pressure over 65 mmHg and were mechanically ventilated with a 'lung-protective' strategy, and whether administering a fluid bolus was associated with a change in PVI (Δ PVI). In this study, fluid responsiveness was defined as an increase in stroke volume of greater than 15% after a 500 ml bolus of colloid infusion over 20 minutes. Of the 25 patients included in the study, only 12 (48%) were considered fluid responders. As static haemodynamic parameters, PVI, central venous pressure and inferior vena cava distensibility index were all inaccurate at predicting volume responsiveness with PVI being the least accurate (area under the receiver operating characteristic curve=0.41, 95% confidence interval 0.18 to 0.65). However, fluid responsiveness was associated with a change in PVI, but not a change in heart rate or central venous pressure. This association between Δ PVI and fluid responsiveness may be a surrogate marker of improved cardiac output following a fluid bolus and warrants further investigation.

Details

UN Sustainable Development Goals (SDGs)

This output has contributed to the advancement of the following goals:

#3 Good Health and Well-Being

Source: InCites

Metrics

InCites Highlights

These are selected metrics from InCites Benchmarking & Analytics tool, related to this output

Citation topics
1 Clinical & Life Sciences
1.154 Assisted Ventilation
1.154.360 Procalcitonin
Web Of Science research areas
Anesthesiology
Critical Care Medicine
ESI research areas
Clinical Medicine
Logo image