Logo image
Biomechanical comparison of a notched head locking T-plate and a straight locking compression plate in a juxta-articular fracture model
Journal article   Peer reviewed

Biomechanical comparison of a notched head locking T-plate and a straight locking compression plate in a juxta-articular fracture model

G. Bird, M. Glyde, G. Hosgood, A. Hayes and R. Day
Veterinary and Comparative Orthopaedics and Traumatology, Vol.34(03), pp.161-170
2021
url
Link to Published Version *Subscription may be requiredView

Abstract

Objective: This investigation compared the biomechanical properties of a 2.0 mm locking compression notched head T-plate (NHTP) and 2.0 mm straight locking compression plate (LCP), in a simple transverse juxta-articular fracture model. Study Design: Two different screw configurations were compared for the NHTP and LCP, modelling short (configuration 1) and long working length (configuration 2). Constructs were tested in compression, perpendicular and tension non-destructive four point bending and torsion. Plate surface strain was measured at 12 regions of interest (ROI) using three-dimensional digital image correlation. Stiffness and strain were compared between screw configurations within and between each plate. Results: The LCP was stiffer than the NHTP in all three planes of bending and torsion (p < 0.05). The NHTP had greater strain than the LCP during compression bending and torsion at all ROI (p < 0.0005). The short working length was stiffer in all three planes of bending and in torsion (p < 0.05) than the longer working length for both plates. The long working length showed greater strain than the short working length at most ROI. Conclusion: In this experimental model, a 2.0 mm LCP with two screws in the short fragment was significantly stiffer and had lower plate strain than a 2.0 mm NHTP with three screws in the short fragment. Extending the working length significantly reduced construct stiffness and increased plate strain. These findings may guide construct selection.

Details

UN Sustainable Development Goals (SDGs)

This output has contributed to the advancement of the following goals:

#3 Good Health and Well-Being

Source: InCites

Metrics

InCites Highlights

These are selected metrics from InCites Benchmarking & Analytics tool, related to this output

Collaboration types
Domestic collaboration
Citation topics
1 Clinical & Life Sciences
1.34 Orthopedics
1.34.800 Fracture Management
Web Of Science research areas
Veterinary Sciences
Zoology
ESI research areas
Plant & Animal Science
Logo image