Logo image
Can bronchoconstriction and bronchodilatation in horses be detected using electrical impedance tomography?
Journal article   Open access   Peer reviewed

Can bronchoconstriction and bronchodilatation in horses be detected using electrical impedance tomography?

C. Secombe, A. Adler, G. Hosgood, A. Raisis and M. Mosing
Journal of Veterinary Internal Medicine, Vol.35(4), pp.2035-2044
2021
pdf
bronchodilatation.pdfDownloadView
Published (Version of Record) Open Access
url
Free to Read *No subscription requiredView

Abstract

Background Electrical impedance tomography (EIT) generates images of the lungs based on impedance change and was able to detect changes in airflow after histamine challenge in horses. Objectives To confirm that EIT can detect histamine‐provoked changes in airflow and subsequent drug‐induced bronchodilatation. Novel EIT flow variables were developed and examined for changes in airflow. Methods Bronchoconstriction was induced using stepwise histamine bronchoprovocation in 17 healthy sedated horses. The EIT variables were recorded at baseline, after saline nebulization (control), at the histamine concentration causing bronchoconstriction (Cmax) and 2 and 10 minutes after albuterol (salbutamol) administration. Peak global inspiratory (PIFEIT) and peak expiratory EIT (PEFEIT) flow, slope of the global expiratory flow‐volume curve (FVslope), steepest FVslope over all pixels in the lung field, total impedance change (surrogate for tidal volume; VTEIT) and intercept on the expiratory FV curve normalized to VTEIT (FVintercept/VTEIT) were indexed to baseline and analyzed for a difference from the control, at Cmax, 2 and 10 minutes after albuterol. Multiple linear regression explored the explanation of the variance of Δflow, a validated variable to evaluate bronchoconstriction using all EIT variables. Results At Cmax, PIFEIT, PEFEIT, and FVslope significantly increased whereas FVintercept/VT decreased. All variables returned to baseline 10 minutes after albuterol. The VTEIT did not change. Multivariable investigation suggested 51% of Δflow variance was explained by a combination of PIFEIT and PEFEIT. Conclusions and Clinical Importance Changes in airflow during histamine challenge and subsequent albuterol administration could be detected by various EIT flow volume variables.

Details

UN Sustainable Development Goals (SDGs)

This output has contributed to the advancement of the following goals:

#3 Good Health and Well-Being

Source: InCites

Metrics

29 File views/ downloads
86 Record Views

InCites Highlights

These are selected metrics from InCites Benchmarking & Analytics tool, related to this output

Collaboration types
Domestic collaboration
International collaboration
Citation topics
3 Agriculture, Environment & Ecology
3.232 Veterinary Sciences
3.232.2141 Equine Respiratory Disorders
Web Of Science research areas
Veterinary Sciences
ESI research areas
Plant & Animal Science
Logo image