Logo image
Co-treatment of septage in a municipal sewage treatment pond system
Journal article   Peer reviewed

Co-treatment of septage in a municipal sewage treatment pond system

B. Kurup, R. Kurup, K. Mathew and G. Ho
Water Science & Technology, Vol.46(9), pp.315-321
2002
url
Link to Published Version *Subscription may be requiredView

Abstract

This paper deals with the characteristics and treatment options of septage. The objective of the paper is to evaluate the effects of co-treatment of 50 MLD of septage in a sewage treatment pond system. The treatment efficiency of the pond system for BOD5 and Fecal Coliform (FC) has been estimated using a first order kinetics model. The model has predicted that the treatment pond system has a maximum capacity of 8.5 MLD and will have a reserve of 28.3% of its total capacity even after the proposed addition of 50 MLD of septage. Separation of oil and grease from septage prior to discharge into the pond system is recommended.

Details

UN Sustainable Development Goals (SDGs)

This output has contributed to the advancement of the following goals:

#6 Clean Water and Sanitation
#7 Affordable and Clean Energy
#12 Responsible Consumption & Production

Source: InCites

Metrics

InCites Highlights

These are selected metrics from InCites Benchmarking & Analytics tool, related to this output

Citation topics
3 Agriculture, Environment & Ecology
3.83 Bioengineering
3.83.416 Anaerobic Digestion
Web Of Science research areas
Engineering, Environmental
Environmental Sciences
Water Resources
ESI research areas
Environment/Ecology