Comparison of electrical impedance tomography and spirometry-based measures of airflow in healthy adult horses
Journal article   Open access   Peer reviewed

Comparison of electrical impedance tomography and spirometry-based measures of airflow in healthy adult horses

David P Byrne, Ben Keeshan, Giselle L Hosgood, Andy Adler and Martina Mosing
Frontiers in physiology, Vol.14, 1164646
2023
pdf
adult horses1.30 MBDownloadView
CC BY V4.0 Open Access

Abstract

Electrical impedance tomography (EIT) is a non-invasive diagnostic tool for evaluating lung function. The objective of this study was to compare respiratory flow variables calculated from thoracic EIT measurements with corresponding spirometry variables. Ten healthy research horses were sedated and instrumented with spirometry via facemask and a single-plane EIT electrode belt around the thorax. Horses were exposed to sequentially increasing volumes of apparatus dead space between 1,000 and 8,500 mL, in 5–7 steps, to induce carbon dioxide rebreathing, until clinical hyperpnea or a tidal volume of 150% baseline was reached. A 2-min stabilization period followed by 2 minutes of data collection occurred at each timepoint. Peak inspiratory and expiratory flow, inspiratory and expiratory time, and expiratory nadir flow, defined as the lowest expiratory flow between the deceleration of flow of the first passive phase of expiration and the acceleration of flow of the second active phase of expiration were evaluated with EIT and spirometry. Breathing pattern was assessed based on the total impedance curve. Bland-Altman analysis was used to evaluate the agreement where perfect agreement was indicated by a ratio of EIT:spirometry of 1.0. The mean ratio (bias; expressed as a percentage difference from perfect agreement) and the 95% confidence interval of the bias are reported. There was good agreement between EIT-derived and spirometry-derived peak inspiratory [−15% (−46–32)] and expiratory [10% (−32–20)] flows and inspiratory [−6% (−25–18)] and expiratory [5% (−9–20)] times. Agreement for nadir flows was poor [−22% (−87–369)]. Sedated horses intermittently exhibited Cheyne-Stokes variant respiration, and a breath pattern with incomplete expiration in between breaths ( crown-like breaths). Electrical impedance tomography can quantify airflow changes over increasing tidal volumes and changing breathing pattern when compared with spirometry in standing sedated horses.

Details

UN Sustainable Development Goals (SDGs)

This output has contributed to the advancement of the following goals:

#15 Life on Land

Metrics

3 File views/ downloads
75 Record Views

InCites Highlights

These are selected metrics from InCites Benchmarking & Analytics tool, related to this output

Collaboration types
Domestic collaboration
International collaboration
Citation topics
1 Clinical & Life Sciences
1.154 Assisted Ventilation
1.154.277 Mechanical Ventilation
Web Of Science research areas
Physiology
ESI research areas
Biology & Biochemistry
Logo image