Logo image
Concordance of assays designed for the quantification of JAK2V617F: a multicenter study
Journal article   Peer reviewed

Concordance of assays designed for the quantification of JAK2V617F: a multicenter study

E. Lippert, F. Girodon, E. Hammond, J. Jelinek, N.S. Reading, B. Fehse, K. Hanlon, M. Hermans, C. Richardson, S. Swierczek, …
Haematologica, Vol.94(1), pp.38-45
2009
url
Free to Read *No subscription requiredView

Abstract

Background Many different techniques have been designed for the quantification of JAK2V617F allelic burden, sometimes producing discrepant results. Design and Methods JAK2V617F quantification techniques were compared among 16 centers using 11 assays based on quantitative polymerase chain reaction (with mutation-specific primers or probes, or fluorescent resonance energy transfer/melting curve analysis), allele-specific polymerase chain reaction, conventional sequencing or pyrosequencing. Results A first series of blinded samples (granulocyte DNA, n=29) was analyzed. Seven assays (12 centers) reported values inside the mean±2SD; the mean coefficient of variation was 31%. Sequencing techniques lacked sensitivity, and strong discrepancies were observed with four techniques, which could be attributed to inadequate standards or to different modes of expression of results. Indeed, quantification of JAK2V617F in relation to another control gene produced higher than expected values, suggesting the possibility of more than two JAK2 copies/cell. After calibration of assays with common 1% to 100% JAK2V617F standards (dilutions of UKE-1 cells in normal leukocytes), 14 centers tested ten new samples. JAK2V617F allelic burdens greater or equal than 1% were then reliably quantified by five techniques – one allele specific-polymerase chain reaction and four TaqMan allele-specific quantitative polymerase chain reaction assays, including one previously giving results outside the mean±2SD – with a lower mean coefficient of variation (21%). Of these, only the two TaqMan allele-specific quantitative polymerase chain reaction assays with primer-based specificity could detect 0.2% JAK2V617F. Conclusions Techniques expressing the allelic burden as JAK2V617F/total JAK2 and using a common set of standards produced similar quantification results but with variable sensitivity. Calibration to a reference standard improved reproducibility.

Details

UN Sustainable Development Goals (SDGs)

This output has contributed to the advancement of the following goals:

#3 Good Health and Well-Being

Source: InCites

Metrics

InCites Highlights

These are selected metrics from InCites Benchmarking & Analytics tool, related to this output

Collaboration types
Domestic collaboration
International collaboration
Citation topics
1 Clinical & Life Sciences
1.103 Blood Disorders
1.103.1465 Myeloproliferative Neoplasms
Web Of Science research areas
Hematology
ESI research areas
Clinical Medicine
Logo image