Logo image
Diagnostic accuracy of a milk pregnancy-associated glycoprotein ELISA accounting for day since last breeding for pregnancy detection in Holstein cows
Journal article   Open access   Peer reviewed

Diagnostic accuracy of a milk pregnancy-associated glycoprotein ELISA accounting for day since last breeding for pregnancy detection in Holstein cows

Simon Dufour, Jean Durocher, Geoffrey Fosgate, Peter C. Irons, Stephen J. LeBlanc and Elouise Molgat
Preventive veterinary medicine, Vol.256, 106988
2026
PMID: 42641436
pdf
Published3.52 MBDownloadView
Open Access CC BY V4.0

Abstract

Dairy cattle Diagnosis Glycoprotein Pregnancy Test Ultrasound
Tests detecting pregnancy-associated glycoproteins (PAG) are widely used for pregnancy diagnosis in dairy cows. Recently, a days-since-last-breeding (DSLB)–specific interpretation algorithm was proposed to account for known fluctuations in PAG concentrations during early gestation. Our objective was to evaluate the diagnostic accuracy and predictive values of this DSLB-specific interpretation for a milk-based commercially available pregnancy test (milk PAG-ELISA) compared with the manufacturer's uniform interpretation thresholds. Data were assembled from two published diagnostic validation studies conducted in Canada and South Africa, including 1260 Holstein cows from 24 commercial dairy herds tested between 28 and 50 DSLB. Milk PAG-ELISA results from manually collected samples were compared with veterinary ultrasonography examinations. Diagnostic accuracy was estimated using a Bayesian latent class model accounting for the imperfect nature of both tests and allowing accuracy to vary across DSLB intervals. When compared with the manufacturer's interpretative thresholds, the DSLB-specific grid improved PAG-ELISA specificity and positive predictive value for cows tested between 41 and 50 DSLB (+12 and +7 %age-point increases, respectively), while yielding similar accuracy for cows tested between 28 and 40 DSLB. However, pregnancy diagnosis in the 41–50 DSLB interval showed lower overall accuracy and predictive values regardless of the interpretation approach used, likely reflecting the physiological decline in PAG concentrations during that stage of gestation. These findings support the use of the novel interpretation grid to improve test performance between 41 and 50 DSLB and indicate that the accuracy of pregnancy diagnosis using milk PAG-ELISA was greater between 28 and 40 DSLB.

Details

UN Sustainable Development Goals (SDGs)

This output has contributed to the advancement of the following goals:

#12 Responsible Consumption & Production
#15 Life on Land

Source: SDGs in the Output

Metrics

2 Record Views
Logo image