Logo image
Distal normograde intramedullary pin and locking plate placement in the canine humerus: A cadaveric study
Journal article   Open access   Peer reviewed

Distal normograde intramedullary pin and locking plate placement in the canine humerus: A cadaveric study

T. Pearson, M. Glyde, G. Hosgood and L. Beierer
Veterinary Surgery, Vol.45(7), pp.879-886
2016
pdf
distal-normograde-intramedullary-pin-and-locking-plate.pdfDownloadView
Author’s Version Open Access
url
Link to Published Version *Subscription may be requiredView

Abstract

Objective: To identify a repeatable anatomic landmark for pin insertion and to describe the technique for placement of a distal normograde intramedullary (IM) pin of approximately 35% of the IM diameter using this approach combined with a locking compression plate (LCP) on the medial aspect of the canine humerus. Study Design: Ex vivo anatomic study. Sample Population: Canine cadavers (n=10 Greyhounds). Methods: An anatomic landmark for pin insertion was identified based on three-dimensional reconstructions of previous elbow computed tomography studies and cadaveric dissection of the medial aspect of the humeral condyle. Bilateral distal normograde IM pin and LCP placement were performed and confirmed radiographically and by disarticulation and sagittal sectioning. Results: The anatomic landmark for pin insertion was consistently identified in each specimen using the technique described. Distal normograde insertion of a 3.5 mm IM pin was possible in Greyhound cadaveric humeri at the described location in conjunction with a 3.5 mm LCP with fixed angle, locked screws. A monocortical locking screw was required to avoid interference with the IM pin in 28 of 60 of the 3 proximal screw holes. No pin interference was encountered in any of the distal screw holes. Conclusion: The anatomic landmark and technique described in our study enabled repeatable successful placement of a distal normograde IM pin of approximately 35% of the IM diameter combined with an LCP on the medial aspect of the canine humerus. This technique may be useful for locking plate-rod fixation of distal humeral diaphyseal fractures.

Details

UN Sustainable Development Goals (SDGs)

This output has contributed to the advancement of the following goals:

#3 Good Health and Well-Being

Source: InCites

Metrics

439 File views/ downloads
223 Record Views

InCites Highlights

These are selected metrics from InCites Benchmarking & Analytics tool, related to this output

Citation topics
1 Clinical & Life Sciences
1.34 Orthopedics
1.34.800 Fracture Management
Web Of Science research areas
Veterinary Sciences
ESI research areas
Plant & Animal Science
Logo image