Effect of Plate-Bone distance and working length on 2.0-mm locking construct stiffness and plate strain in a Diaphyseal Fracture Gap Model: A Biomechanical Study
Journal article   Peer reviewed

Effect of Plate-Bone distance and working length on 2.0-mm locking construct stiffness and plate strain in a Diaphyseal Fracture Gap Model: A Biomechanical Study

Alecia Evans, Mark Glyde, Rob Day and Giselle Hosgood
Veterinary and comparative orthopaedics and traumatology
2023
PMID: 37473771

Abstract

Objective The aim of this study was to determine the effect of plate–bone distance (PBD) and working length on 2.0-mm locking compression plate (LCP) stiffness and strain in four-point bending and torsion in a diaphyseal fracture gap model. Study Design A total of 54 LCP with three screws per fragment were assigned to one of nine combinations of working length (WL; short, medium, and long), and PBD (1, 1.5, and 3 mm) for a sample size of six per construct configuration. Stiffness was measured under quasistatic, nondestructive four-point compression bending and torsion. Plate surface strain was recorded using three-dimensional (3D) digital image correlation during four-point compression bending. Results WL had a significant effect on overall construct stiffness in both compression bending and in torsion, with shorter WL constructs having higher stiffness (p < 0.0001). PBD had no effect on construct stiffness in compression bending; however, a significant reduction in stiffness was noted in torsion (p = 0.047) as PBD incrementally increased. WL had a significant effect on plate strain in compression bending, with shorter WL constructs having lower plate strain (p < 0.0001). PBD had no effect on plate strain in compression bending except for lower plate strain recorded in long WL constructs with 1-mm PBD, compared with 1.5- and 3-mm PBD constructs (p < 0.0001). Conclusions Longer WL constructs, regardless of PBD, had lower stiffness in compression bending, while in torsion, some modulation of this effect was noted with incremental decreases in PBD. Longer WL resulted in high plate strain, regardless of PBD.

Details

UN Sustainable Development Goals (SDGs)

This output has contributed to the advancement of the following goals:

#3 Good Health and Well-Being

Source: InCites

Metrics

InCites Highlights

These are selected metrics from InCites Benchmarking & Analytics tool, related to this output

Collaboration types
Domestic collaboration
Citation topics
1 Clinical & Life Sciences
1.34 Orthopedics
1.34.800 Fracture Management
Web Of Science research areas
Veterinary Sciences
Zoology
ESI research areas
Plant & Animal Science
Logo image