Effects of contrast medium injection technique on attenuation values of adrenal glands in healthy dogs during contrast-enhanced computed tomography
Journal article   Peer reviewed

Effects of contrast medium injection technique on attenuation values of adrenal glands in healthy dogs during contrast-enhanced computed tomography

Alexandra Blaser, Matthias Dennler, Martina Mosing, Thomas C. Gent, Guido Santner, Sandro Imhasly, Felicitas S. Boretti, Claudia E. Reusch, Patrick Kircher and Nadja S. Sieber-Ruckstuhl
American journal of veterinary research, Vol.77(2), pp.144-150
2016
PMID: 27027707

Abstract

Life Sciences & Biomedicine Science & Technology Veterinary Sciences
OBJECTIVE To assess the effects of 3 contrast medium injection techniques on attenuation values for canine adrenal glands during contrast-enhanced CT. ANIMALS 9 healthy Beagles. PROCEDURES 3 protocols were evaluated in a randomized cross-over design study: 700 mg of iodine/kg at a constant injection rate over 20 seconds (full-dose constant rate), the same dose at a rate following an exponential decay curve over 20 seconds (full-dose decelerated rate), and 350 mg of iodine/kg at a constant injection rate over 10 seconds (half-dose constant rate). Multislice CT images were obtained before and at predetermined time points after the start of contrast medium injection. RESULTS Median peak attenuation values were 129, 133, and 87 Hounsfield units with the full-dose constant rate, full-dose decelerated rate, and half-dose constant rate injection protocols, respectively. Peak attenuation differed significantly between the full-dose constant rate and half-dose constant rate injection protocols and between the full-dose decelerated rate and half-dose constant rate injection protocols. Median time to peak attenuation did not differ significantly among injection methods and was 30, 23, and 15 seconds for the full-dose constant rate, full-dose decelerated rate, and half-dose constant rate injections, respectively. CONCLUSIONS AND CLINICAL RELEVANCE The dose of contrast medium and the timing of postinjection CT scanning were main determinants of peak attenuation for adrenal glands in healthy dogs; effects of the 3 injection protocols on attenuation were minor. The exponentially decelerated injection method was subjectively complex. A constant injection protocol delivering 700 mg of iodine/kg over 20 seconds, with scans obtained approximately 30 seconds after starting contrast medium injection, provided images with maximum adrenal gland attenuation values.

Details

UN Sustainable Development Goals (SDGs)

This output has contributed to the advancement of the following goals:

#3 Good Health and Well-Being

Source: InCites

Metrics

InCites Highlights

These are selected metrics from InCites Benchmarking & Analytics tool, related to this output

Collaboration types
Domestic collaboration
Citation topics
1 Clinical & Life Sciences
1.71 Cardiology - Circulation
1.71.1425 Coronary CT Angiography
Web Of Science research areas
Veterinary Sciences
ESI research areas
Plant & Animal Science
Logo image