Objective Evaluation of the accuracy of Masimo signal extraction technology (SET) pulse oximetry in anaesthetized late gestational pregnant sheep. Study design Prospective experimental study. Animals Seventeen pregnant Merino ewes. Methods Animals included in study were late gestation ewes undergoing general anaesthesia for Caesarean delivery or foetal surgery in a medical research laboratory. Masimo Radical-7 pulse oximetry (SpO2) measurements were compared to co-oximetry (SaO2) measurements from arterial blood gas analyses. The failure rate of the pulse oximeter was calculated. Accuracy was assessed by Bland & Altman's (2007) limits of agreement method. The effect of mean arterial blood pressure (MAP), perfusion index (PI) and haemoglobin (Hb) concentration on accuracy were assessed by regression analysis. Results Forty arterial blood samples paired with SpO2 and blood pressure measurements were obtained. SpO2 ranged from 42 to 99% and SaO2 from 43.7 to 99.9%. MAP ranged from 24 to 82mmHg, PI from 0.1 to 1.56 and Hb concentration from 71 to 114gL-1. Masimo pulse oximetry measurements tended to underestimate oxyhaemoglobin saturation compared to co-oximetry with a bias (mean difference) of -2% and precision (standard deviation of the differences) of 6%. Accuracy appeared to decrease when SpO2 was <75%, however numbers were too small for statistical comparisons. Hb concentration and PI had no significant effect on accuracy, whereas MAP was negatively correlated with SpO2 bias. Conclusions and clinical relevance Masimo SET pulse oximetry can provide reliable and continuous monitoring of arterial oxyhaemoglobin saturation in anaesthetized pregnant sheep during clinically relevant levels of cardiopulmonary dysfunction. Further work is needed to assess pulse oximeter function during extreme hypotension and hypoxaemia.
Details
- Title
- Evaluation of Masimo signal extraction technology pulse oximetry in anaesthetized pregnant sheep
- Authors/Creators
- C.T. Quinn (Author/Creator) - Murdoch UniversityA.L. Raisis (Author/Creator) - Murdoch UniversityG.C. Musk (Author/Creator) - Murdoch University
- Publication Details
- Veterinary Anaesthesia and Analgesia, Vol.40(2), pp.149-156
- Publisher
- Blackwell Publishing Inc.
- Identifiers
- 991005543579207891
- Copyright
- © 2012 The Authors.
- Murdoch Affiliation
- School of Veterinary and Biomedical Sciences
- Language
- English
- Resource Type
- Journal article
UN Sustainable Development Goals (SDGs)
This output has contributed to the advancement of the following goals:
Source: InCites
Metrics
28 Record Views
InCites Highlights
These are selected metrics from InCites Benchmarking & Analytics tool, related to this output
- Collaboration types
- Domestic collaboration
- Citation topics
- 1 Clinical & Life Sciences
- 1.55 Urology & Nephrology - General
- 1.55.860 Arterial Stiffness
- Web Of Science research areas
- Veterinary Sciences
- ESI research areas
- Plant & Animal Science