Logo image
Flow cytometry analysis with a new FITC-Conjugated monoclonal antibody-3E12 for HLA-B*57:01 rapid screening in prevention of abacavir hypersensitivity in HIV-1–infected patients
Journal article   Peer reviewed

Flow cytometry analysis with a new FITC-Conjugated monoclonal antibody-3E12 for HLA-B*57:01 rapid screening in prevention of abacavir hypersensitivity in HIV-1–infected patients

C. Rodríguez-Sáinz, L. Valor, D.C. Hernández, J. Gil, J. Carbone, M. Pascual-Bernaldez, F. Rodríguez-Alcántara, I. Martínez, J.L. Vicario, S. Mallal, …
HIV Clinical Trials, Vol.14(4), pp.160-164
2013
url
Link to Published Version *Subscription may be requiredView

Abstract

Background: Rapid screening for the detection of HLA-B*57:01 in the prevention of abacavir hypersensitivity in HIV-1-infected patients is a hallmark for clinical services. Objective: The aim of this work was to analyze the utility of flow cytometry with a new FITC-conjugated B-17 monoclonal antibody (mAb3E12) for HLA-B*57:01 screening in a Spanish cohort of 577 HIV-1+ individuals. Methods: Cryopreserved peripheral blood mononuclear cell samples from HIV-1+ individuals were analyzed by flow cytometry with the mAb 3E12 that recognizes both HLA-B*57 and HLA-B*58 alleles (members of the group specificity, HLA-B17). Patients' DNA samples had been previously typed for HLA-B*57:01 with PCR-SSO or PCR-SSP and additional DNA sequencing (EPI Study). The results obtained by flow cytometry were compared with the results obtained by the DNA-PCR techniques. Results: By flow cytometry, 46 samples (7.97%) were positive for HLA-B17, 530 (91.86%) were negative, and 1 (0.17%) was undetermined. All samples found negative by flow cytometry were negative for HLA-B*57:01 by DNA-PCR. Of the HLA-B17 positive samples, 31 (67.4%) were positive for HLA-B*57:01, 2 (3.25%) were positive for HLA-B*57:03, 11 (26.1%) were positive for HLA-B*58, and 2 (3.25%) were negative for both HLA-B*57 and HLA-B*58 antigens. The undetermined sample was negative for HLA-B*57 and HLA-B*58 alleles by DNA-PCR. Conclusions: This study shows that flow cytometry with mAb3E12 is a highly sensitive method (no false negatives) to implement prior to DNA-PCR analysis for rapid screening of HLA-B*57:01. Additional confirmation by molecular HLA typing method would be required in less than 10% of the cohort of HIV-1-infected individuals.

Details

UN Sustainable Development Goals (SDGs)

This output has contributed to the advancement of the following goals:

#3 Good Health and Well-Being

Source: InCites

Metrics

InCites Highlights

These are selected metrics from InCites Benchmarking & Analytics tool, related to this output

Collaboration types
Industry collaboration
Domestic collaboration
International collaboration
Citation topics
1 Clinical & Life Sciences
1.265 Dermatology - Skin Allergies
1.265.1140 Drug Hypersensitivity
Web Of Science research areas
Infectious Diseases
Pharmacology & Pharmacy
ESI research areas
Clinical Medicine
Logo image