anesthesia blood flow Doppler ultrasound equine phenylephrine sodium nitroprusside waveform analysis
The purpose of the study was to determine the ability of Doppler ultrasound to detect changes in femoral blood flow during pharmacologic manipulation of arterial blood pressure. Doppler ultrasonography was performed in the femoral vessels of six halothane-anesthetized horses before and during administration of phenylephrine HC1 and sodium nitroprusside. The time-averaged mean velocity and volumetric flow were calculated. The contour of the velocity waveform was assessed, and the early diastolic deceleration slope (EDDS) and pulsatility index (PI) were calculated. Administration of phenylephrine HO resulted in increased mean aortic blood pressure (MABP) by 40% (29.3–53.0%). This caused significant decrease in cardiac output (26.8 to 13.5 1/min), femoral arterial velocity (left artery 7.20 to 4.00 cm/s; right artery 5.01 to 3.39 cm/s) and volumetric flow (left artery 556 to 221 ml/min; right artery 397 to 193 ml/min) in the femoral vessels and significant increase in systemic vascular resistance (163 to 433 dyn-s/cms), EDDS (la: 285 to 468: ra: 250 to 481) and PI (la: 9.38 to 20.4; ra 17.1 to 29.1). Administration of sodium nitroprusside resulted in a decreased MABP of 27.2% (22.5–33%). This increased cardiac output (20.8 to 32.4 L/min), however, no significant changes were observed in femoral blood flow. Despite obvious changes in the waveform contour, no significant change occurred in EDDS or PL These results suggest that Doppler ultrasound may be useful for measuring femoral blood flow in anesthetized horses. However, waveform analysis appears to be limited when multiple changes occur in central and peripheral haemodynamics.

Details

UN Sustainable Development Goals (SDGs)

This output has contributed to the advancement of the following goals:

#3 Good Health and Well-Being

Source: InCites

Metrics

InCites Highlights

These are selected metrics from InCites Benchmarking & Analytics tool, related to this output

Collaboration types
Domestic collaboration
Citation topics
1 Clinical & Life Sciences
1.43 Anesthesiology
1.43.1642 Veterinary Anesthesia
Web Of Science research areas
Veterinary Sciences
ESI research areas
Plant & Animal Science
Logo image