The use of electrical impedance tomography (EIT) to evaluate pulse rate in anaesthetised horses
Journal article   Peer reviewed

The use of electrical impedance tomography (EIT) to evaluate pulse rate in anaesthetised horses

A.L. Raisis, M. Mosing, G.L. Hosgood, C.J. Secombe, A. Adler and A.D. Waldmann
The Veterinary Journal, Vol.273, Art. 105694
2021
url
Link to Published Version *Subscription may be requiredView

Abstract

Electrical impedance tomography (EIT) provides clinically useful lung images; however, it would be an advantage to extract additional cardiovascular information from the data. The aim of this study was to evaluate if cardiac-related changes measured by EIT can be used to measure pulse rate (PR) under physiological as well as high and low blood pressure states in anaesthetised horses. Electrical impedance tomography data and PR from seven horses anaesthetised in dorsal recumbency were recorded over 1 min during mechanical ventilation and 1 min of apnoea. Data were collected at four measurement time points; before and during intravenous administration of nitroprusside and phenylephrine, respectively. Nine pixels, estimated to represent the heart, were chosen from the EIT image. A novel algorithm detected peaks of impedance change for these pixels over 10 s intervals. Concurrent PR measured using an invasive blood pressure trace, was recorded every 10 s. EIT- and pulse-rate data were compared using Bland-Altman assessment for multiple measurements on each horse. Overall, 288 paired datasets from six of seven horses were available for analysis. There was excellent agreement for baseline measurements, as well as during hypertension and hypotension, with a bias of −0.26 and lower and upper limit of agreement at −2.22 (95% confidence intervals [CI], −2.89 to −1.86) and 1.69 (95% CI, 1.34–2.36) beats per min, respectively. EIT can be used to evaluate PR using cardiac-related impedance changes. More work is required to determine bias that might occur in anaesthetised horses in other recumbencies or clinical situations.

Details

UN Sustainable Development Goals (SDGs)

This output has contributed to the advancement of the following goals:

#3 Good Health and Well-Being

Source: InCites

Metrics

InCites Highlights

These are selected metrics from InCites Benchmarking & Analytics tool, related to this output

Collaboration types
Domestic collaboration
International collaboration
Citation topics
8 Earth Sciences
8.212 Sensors & Tomography
8.212.1753 Electrical Impedance Tomography
Web Of Science research areas
Veterinary Sciences
ESI research areas
Plant & Animal Science
Logo image