Variability associated with repeated measurements of gastrointestinal tract motility in dogs obtained by use of a wireless motility capsule system and scintigraphy
Journal article   Open access   Peer reviewed

Variability associated with repeated measurements of gastrointestinal tract motility in dogs obtained by use of a wireless motility capsule system and scintigraphy

C.S. Boillat, F.P. Gaschen, L. Gaschen, R.W. Stout and G.L. Hosgood
American Journal of Veterinary Research, Vol.71(8), pp.903-908
2010
pdf
Published592.83 kBDownloadView
Published (Version of Record)CC BY-NC V4.0 Open Access

Abstract

Objective To compare repeatability of measurements of gastrointestinal tract motility in healthy dogs obtained by use of a wireless motility capsule (WMC) and scintigraphy. Animals 6 healthy adult dogs (mean ± SD body weight, 21.5 ± 1.8 kg). Procedures A radiolabeled test meal was offered immediately after oral administration of a WMC. Serial static scintigraphic abdominal images were acquired for 270 minutes. A dedicated remote receiver was used for data collection from the WMC until the WMC was expelled in the feces. Each dog was evaluated 3 times at intervals of 1 to 2 weeks. Results Mean gastric emptying half-time measured by use of scintigraphy (T1/2-GES) for each dog ranged from 99.9 to 181.2 minutes. Mean gastric emptying time (GET) measured by use of the WMC (GET-WMC) in each dog ranged from 385.3 to 669.7 minutes. Mean coefficient of variation was 11.8% for T1/2-GES and 7.8% for GET-WMC. The intraclass correlation coefficient was 69% for T1/2-GES and 71% for GET-WMC. Results for a nested analysis of covariance suggested that both methods were comparable for the evaluation of gastric emptying. Conclusions and Clinical Relevance—Scintigraphy and a WMC system had similar variation for assessment of gastric emptying. Moderate intraindividual variability was detected for both methods and must be considered when interpreting test results for individual dogs. Repeatability of measurements obtained by use of the WMC was equivalent to that obtained by use of scintigraphy. The WMC system offers a nonradioactive, user-friendly method for assessment of gastric emptying in dogs.

Details

UN Sustainable Development Goals (SDGs)

This output has contributed to the advancement of the following goals:

#3 Good Health and Well-Being

Source: InCites

Metrics

30 File views/ downloads
59 Record Views

InCites Highlights

These are selected metrics from InCites Benchmarking & Analytics tool, related to this output

Collaboration types
Domestic collaboration
Citation topics
1 Clinical & Life Sciences
1.95 Gastrointestinal & Esophageal Diseases
1.95.723 IBS & Functional Disorders
Web Of Science research areas
Veterinary Sciences
ESI research areas
Plant & Animal Science
Logo image